DicksonOne Touchscreen Data Logger

Model: TWE

Choose a base touchscreen. Both options here are DicksonOne enabled touchscreens meaning they connect to the internet and send data to your DicksonOne account. We also have non-internet connected touchscreen available too.

The difference between the two options are how you want to power that device. These devices require power to operate properly (but they do have battery backups) but Power over Ethernet (PoE) does offer greater flexibility if your facility supports it. Ask IT if you're unsure.

Enquiry
  • Data Logger Specifications
  • Sensor Specifications

Data Logger Specifications

Alarm Type Audible/Visual (Phone, Text, and Email Alarms via DicksonOne Subscription)
Ambient Operating RH Conditions 0 to 95% RH non-condensing (Logger Only)
Ambient Operating Temperature Conditions TWE: 32.0 to 158.0F (0.0 to 70.0C)
TWP: 32.0 to 140.0F (0.0 to 60.0C)
Antenna Type Internal
Approvals CE
Backup Battery 70 Hours
Battery Type Rechargeable Backup Battery
Cable Details Up to 5 Probe Extensions (A898) can be used (50ft Total)
Calibration Options N100, N300, N400, N995
Data Capacity Approx 1,000,000 sample points (backup)
Dimensions 8.5 x 1.75 x 7.0" (21.0 x 4.5 x 18.0cm)
Display Dimensions 8" Diagonal
Display Type LCD Touchscreen
Display Update Rate Sample Interval Dependent (User Selectable)
Download Type WiFi/Ethernet (DicksonOne Cloud), USB (must be formatted at FAT32)
Enclosure Case Front: Polycarbonate; Case Back and Pods; ABS
Included Accessories AC Adapter, Mounting Bracket and Kickstand
Input Current Peak TWP: (At 48V) 235mA
Input Voltage Range TWP: 36.0 to 57.0V
Mounting Options Mounting Bracket (Included with Touchscreen)
PC Requirements Windows 7 or more recent
Power Consumption TWP: Up to 9W
Power Cord 6 ft
Power Source 100-240 VAC 50/60Hz 12V=1A
Required Software DicksonOne SaaS Package, DicksonWare VERSION TBD
Resolution LCD TBD
Sample Interval User Selectable Sample Intervals: 60, 90 seconds / 2, 5, 10, 15, 30, 60 minutes. (10 and 30 seconds optional, please call for details)
Sensor Type Replaceable Sensor (See Accessories for more information)
Unit Weight 1.45lbs
Units/Pkg 1
Warranty 12-month

Sensor Specifications

Sensor Description SKU Specifications
Ambient Temperature & Humidity Replaceable Sensor RTRH
RTRH-R
Ambient Operating RH Conditions : 5 to 95% RH (non-condensing)
Humidity Accuracy: +/-2.0% RH from 5.0 to 95.0% RH
Humidity Range: 5 to 95% RH (non-condensing)
Temperature Accuracy: +/-0.8F from 20.0 to 120.0F 1.8F (+/-0.4C from -6.7 to 50.0C 1.0C)
Temperature Range:-40.0 to 185.0F (-40.0 to 85.0C)
Single Thermistor Replacaebale Sensor (in buffer) RTHM Temperature Accuracy: +/-0.9F from -58.0 to 68.0F 0.0F (+/-0.5C from -58.0 to 20.0C 0.0C)
Temperature Accuracy (Remainder of Range): +/- 1.2F (+/-0.9C) from 69 to 122F (21 to 50C); +/-1.8F (+/-1C) from 123-158F (51- to 70C)
Temperature Range: -58.0 to 158.0F (-50.0 to 70.0C)
Dual Thermistor Replacaebale Sensor (in buffer) RTHM2 Temperature Accuracy: +/-0.9F from -58.0 to 68.0F (+/-0.5C from -50.0 to 20.0C)
Temperature Accuracy (Remainder of Range): +/- 1.2F (+/-0.9C) from 69 to 122F (21 to 50C); +/-1.8F (+/-1C) from 123-158F (51- to 70C)
Temperature Range: -58.0 to 158.0F (-50.0 to 70.0C)
K-Thermocouple Replaceable Sensor RKTC Temperature Accuracy: +/-1.8F from -22.0 to 122.0F (+/-1.0C from -30.0 to 50.0C)
Temperature Accuracy (Remainder of Range): +/-3.8 (2.1C)
Temperature Range:-300.0 to 2000.0F (-184.0 to 1093.0C)
Dual K-Thermocouple Replaceable Sensor RKTC2 Temperature Accuracy: +/-1.8F from -22.0 to 122.0F 3.8F (+/-1.0C from -30.0 to 50.0C 2.1C)
Temperature Range: -300.0 to 2000.0F (-184.0 to 1093.0C)
Platinum RTD Replaceable Sensor RRTD Cable Length: 6.0ft (182.0cm)
Temperature Accuracy: +/-0.5F from -148.0 to 350.0F (+/-0.3C from -100.0 to 176.0C)
Temperature Range:-148.0 to 350.0F (-100.0 to 176.0C)
Ambient Temperature Replaceable Sensor RTMP
RTMP-R
Temperature Accuracy: +/-1.2F from 20.0 to 122.0F (+/-0.7C from -7.0 to 50.0C)
Temperature Range: -22.0 to 122.0F (-30.0 to 50.0C)
Differential Pressure Replaceable Sensor (2") RS080 Differential Pressure Accuracy: +/-3.0% from -2.0 to 2.0inH20
Resolution: 0.000
Differential Pressure Replaceable Sensor (0.5") RS081 Differential Pressure Accuracy: +/-3.0% from -0.5 to 0.5inH20
Resolution: 0.000